1275
137
FAIL
The Endpoint 1 SNI’s administered neighbor does not match the physical
neighbor connected. Use list fiber-link to see a fiber link’s
endpoints. The SNI’s assigned neighbor is an EI, but the SNI is physically
connected to another SNI. Enter list fiber-link and verify that the
fiber-optic and metallic cables are installed as administered.
138
FAIL
The physical location of SNI Endpoint 1’s neighbor does not match its
administered location. Use list fiber-link to see a fiber link’s
administered location. Use list fiber-link to see a fiber link’s
endpoints. One location (carrier and slot) is assigned for the endpoint’s
neighbor, but it physically resides in another location.
neighbor, but it physically resides in another location.
1. Enter list fiber-link and verify that the fiber-optic and metallic
cables are installed as administered.
2. If the problem does not seem to be caused by either a
physical-connection or an administration problem, replace the
neighbor circuit pack. The neighbor circuit pack may have a hardware
problem causing it to report a wrong angel address (physical carrier/
slot address) to software.
neighbor circuit pack. The neighbor circuit pack may have a hardware
problem causing it to report a wrong angel address (physical carrier/
slot address) to software.
139
FAIL
The Endpoint 1 SNI is administered to be connected to a DS1 converter, but
is not physically connected to one. Use list fiber-link to see a fiber
link’s endpoints.
If a DS1 converter should be connected to this SNI, enter list
If a DS1 converter should be connected to this SNI, enter list
fiber-link and verify that the fiber-optic and/or metallic cables are
installed as assigned.
If not, change administration to remove the DS1 converter complex from
the SNI’s fiber link:
If not, change administration to remove the DS1 converter complex from
the SNI’s fiber link:
1. Enter list fiber-link to locate the fiber with this SNI as an
endpoint
2. Enter remove fiber-link to remove the fiber
3. Enter add fiber-link to add the fiber back, without assigning the
3. Enter add fiber-link to add the fiber back, without assigning the
DS1 converter complex
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
11 of 22