Avaya 03-300430 User Manual
FIBER-LK (Fiber Link)
Issue 1 June 2005
1285
236
FAIL
The Endpoint 2 SNI’s administered neighbor does not match the physical
neighbor connected. Use list fiber-link to see a fiber link’s
endpoints. The SNI’s assigned neighbor is another SNI, but the SNI is
physically connected to an EI. Enter list fiber-link and verify that the
fiber-optic and metallic cables are installed as administered.
237
FAIL
The Endpoint 2 SNI’s administered neighbor does not match the physical
neighbor connected. Use list fiber-link to see fiber link endpoints.
The SNI’s assigned neighbor is an EI, but the SNI is physically connected to
another SNI. Enter list fiber-link and verify that the fiber-optic and
metallic cables are installed as administered.
238
FAIL
The physical location of SNI Endpoint 2’s neighbor does not match its
administered location. Use list fiber-link to see a fiber link’s
administered location. Use list fiber-link to see a fiber link’s
endpoints. One location (carrier and slot) is assigned for the endpoint’s
neighbor, but it physically resides in another location.
neighbor, but it physically resides in another location.
1. Enter list fiber-link and verify that the fiber-optic and metallic
cables are installed as administered.
2. If the problem does not seem to be caused by either a
physical-connection or an administration problem, replace the
neighbor circuit pack. The neighbor circuit pack may have a hardware
problem causing it to report a wrong angel address (physical carrier/
slot address) to software.
neighbor circuit pack. The neighbor circuit pack may have a hardware
problem causing it to report a wrong angel address (physical carrier/
slot address) to software.
239
FAIL
The SNI Endpoint 2 is assigned to be connected to a DS1 converter, but is
not physically connected to one. Use list fiber-link to see a fiber
link’s endpoints.
If this SNI endpoint should be connected to a DS1 converter:
If this SNI endpoint should be connected to a DS1 converter:
1. Enter list fiber-link to verify that the fiber-optic cable and/or
metallic cable connections are installed as assigned.
If not, change administration to remove the DS1 converter complex from
the SNI’s fiber link:
the SNI’s fiber link:
1. Enter list fiber-link to locate this SNI endpoint’s fiber
2. Enter remove fiber-link for this SNI endpoint’s fiber
3. Enter add fiber-link to replace the fiber without assigning the
2. Enter remove fiber-link for this SNI endpoint’s fiber
3. Enter add fiber-link to replace the fiber without assigning the
DS1 converter complex.
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
21 of 22