236
FAIL
The Endpoint 2 SNI’s administered neighbor does not match the physical 
neighbor connected. Use list fiber-link to see a fiber link’s 
endpoints. The SNI’s assigned neighbor is another SNI, but the SNI is 
physically connected to an EI. Enter list fiber-link and verify that the 
fiber-optic and metallic cables are installed as administered.
237
FAIL
The Endpoint 2 SNI’s administered neighbor does not match the physical 
neighbor connected. Use list fiber-link to see fiber link endpoints. 
The SNI’s assigned neighbor is an EI, but the SNI is physically connected to 
another SNI. Enter list fiber-link and verify that the fiber-optic and 
metallic cables are installed as administered.
238
FAIL
The physical location of SNI Endpoint 2’s neighbor does not match its 
administered location. Use list fiber-link to see a fiber link’s 
endpoints. One location (carrier and slot) is assigned for the endpoint’s 
neighbor, but it physically resides in another location.
1. Enter list fiber-link and verify that the fiber-optic and metallic 
cables are installed as administered.
2. If the problem does not seem to be caused by either a 
physical-connection or an administration problem, replace the 
neighbor circuit pack. The neighbor circuit pack may have a hardware 
problem causing it to report a wrong angel address (physical carrier/
slot address) to software.
239
FAIL
The SNI Endpoint 2 is assigned to be connected to a DS1 converter, but is 
not physically connected to one. Use list fiber-link to see a fiber 
link’s endpoints.
If this SNI endpoint should be connected to a DS1 converter:
1. Enter list fiber-link to verify that the fiber-optic cable and/or 
metallic cable connections are installed as assigned.
If not, change administration to remove the DS1 converter complex from 
the SNI’s fiber link:
1. Enter list fiber-link to locate this SNI endpoint’s fiber
2. Enter remove fiber-link for this SNI endpoint’s fiber
3. Enter add fiber-link to replace the fiber without assigning the 
DS1 converter complex.
Table 440: Test #759 Configuration Audit  (continued)