ABRT
The lightwave transceiver is absent from Endpoint 2 of the fiber link. Use 
list fiber-link to display fiber link endpoints.
1. If a lightwave transceiver should not be present (for example, an SNI 
connected to a DS1 converter circuit pack), do nothing.
2. Otherwise, continue with the following steps.
3. Check the lightwave transceiver connections.
4. Replace the lightwave transceiver.
5. Replace the SNI circuit pack.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The software timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2304
ABRT
The SNI circuit pack responded that it is not able to run the test requested 
by software.
1. Retry the command at 1-minute intervals up to 3 times.