Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1320 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
7
ABRT
Destination unreachable.
1. Verify that the C-LAN has been administered with an IP-Route that 
enables the C-LAN to reach the far-end IP address.
2. Once verified, use test sig-group grp# to verify that the H.323 
Signaling Group Ping test (#1387) passes.
1005
ABRT
Configuration for this test is incorrect.
1. Verity that the link is in service with the status port or status 
link. Verify that the routing table has destinations that are reachable 
through this port.
2. Repeat the test.
3. If the test aborts with Error Code 7, while step 1 verified, escalate the 
problem.
1125
ABRT
 Link is not in service.
1. Check if the link is in service or not. If the link is not in service, release 
the link using release link or release port, and repeat the test. 
This is a normal abort.
2. If the test continues to abort after following the repair procedures, 
escalate the problem.
2000
ABRT
Response to the test was not received from the C-LAN circuit pack within 
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the 
other ports on the board are idle (amber LED is off). Reset the circuit 
pack by issuing busyout board locationreset board 
location
, and release board location.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
The necessary system resources to execute the test could not be 
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
Table 457: Test #1387 H.323 Signaling Group Ping Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3