Avaya 03-300430 User Manual

Page of 2574
H323-STN (H.323 IP Station)
Issue 1 June 2005
1325
 
A registered extension has a port type SNNNNN, where N is a digit from 0–9. A non-registered 
extension has an X port.
Signaling Path PING Test (#1373)
This test is nondestructive.
Signaling Path PING test determines the local C-LAN through which the signaling originates 
and the endpoint’s IP address. It then requests the local C-LAN to execute a PING on the 
endpoint’s address. If the PING is successful, the test passes, if the PING is not successful, the 
test fails.
Note:
Note:
Multiple failures of this test can take the H.323 IP Station out of service.
Note:
Note:
S8300
 / 
G700
: This test does not execute on a G700 Media Gateway.
This test checks the circuitry involved in the data path of a peer-to-peer IP layer connection.
Table 460: Test #1372 Registration Status Inquiry 
Error 
Code
Test 
Result
Description / Recommendation
1,
2,
3
FAIL
The endpoint is not successfully registered.
1. Verify that the user is entering the:
correct extension and security code
C-LAN IP address
2. Verify that the extension has been enabled for IP Softphones 
operation.
3. If many endpoints cannot register, investigate any errors of the C-LAN 
Ethernet port.
4. Examine the Ethernet cabling from the endpoint PC to the Ethernet 
hub.
PASS
The endpoint is successfully registered and continues to respond to 
registration handshaking.