Avaya 03-300430 User Manual

Page of 2574
IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005
1393
 
For logged failures reseat the board to run the test again. If the board still fails, replace the 
board.
Short IP 2-Way Transmission Test (#1505)
This test is nondestructive.
This test attempts to verify IP network connectivity between one pair of IP Media Resources that 
are connected to a customer’s LAN/WAN IP network.
This test creates a G.711 audio path between the source IP Media Resource specified in the 
command line and a destination IP Media Resource. The destination Media Resource is chosen 
by the system. The destination Media Resource is chosen from a port network other than the 
port network containing the source Media Resource. In addition, the destination Media 
Resource is chosen from the same IP network region as the source Media Resource or is 
chosen from an IP network region that is administered to be connected to the IP network region 
of the source Media Resource.
Table 492: Test #1402 Aux Data values
Aux Data Description
Board in 
service?
20481
Field Programmable Gate Array (FPGA) not functioning 
properly. 
No
20482
Super NPE failed FIFO test
No
20483
Unable to start VoIP engine
No
20484
Digital Signal Processors (DSP) not functioning properly
No
20485
Bad initialization on network interface
No
20486
Bad services port - log error only, no alarm
Yes
20487
Packet bus driver interface not functioning properly
No
20488
Network interface 1 not working
No
20489
Network interface 2 not working - log error only, no alarm
Yes
20490
Virtual Network interface not functioning properly
No
20491
Angel interface not functioning properly
No
20492
Spitfire driver not functioning properly
No
20493
Packet bus hardware interface not functioning properly
No