ISDN-SGR (ISDN-PRI Signaling Group)
Issue 1 June 2005
1445
 
Any
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute add ds1 location 
to administer the circuit pack or media module interface if it is not already 
administered.
If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the board is 
shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then enter busyout 
board location.
Enter reset board location.
Enter release location board.
Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 519: Test #647 Layer 2 Status Query Test  (continued)