ISDN-SGR (ISDN-PRI Signaling Group)
Issue 1 June 2005
1443
 
Layer 2 Status Test (#647)
The Layer 2 Status Test checks the layer-2 status of the ISDN-PRI Signaling Channel (D 
channel). This test will fail if there is a hardware failure or a facility problem, or if the primary and 
secondary ISDN-PRI D channels are not administered correctly.
The Primary and Secondary Signaling Link Hardware tests (test 637 and 639) and the Remote 
Layer 3 Query test (#637) will detect most problems caused by hardware failures or incorrect 
administration. However, this layer-3 test cannot detect end-to-end transmission problems with 
the standby D channel since layer-3 messages are not sent on the standby channel.
For systems supporting circuit packs, the SYS-LINK MO reports layer-2 ISDN-PRI D-channel 
problems and the PI-LINK MO reports layer-2 ISDN-PRI D-channel problems (if the D channel 
is connected to the Processor Interface circuit pack). However, for some systems, the PI-LINK 
MO does not monitor the layer-2 status of the ISDN-PRI D channel, when it is connected to the 
Packet Control circuit pack for the ISDN-PRI over PACCON feature. 
The Layer 2 Query test is provided to detect Layer-2 D-Channel failures and generate an 
associated Warning alarm independent of the hardware configuration used for the D channels.
Table 519: Test #647 Layer 2 Status Query Test 
Error 
Code
Test 
Result
Description / Recommendation
1132
ABRT
Internal system error:
The port location for the primary ISDN-PRI D channel is not known. This 
condition should not be possible since an administered DS1 circuit pack or 
media module must be specified when a Signaling Group is administered:
1. Retry the command at 1-minute intervals up to 5 times.
1134
ABRT
Internal system error:
The associated DS1 circuit pack or media module is not administered. This 
condition should not be possible since an administered DS1 circuit pack or 
media module must be specified when a Signaling Group is administered.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error:
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 3