Avaya 03-300430 User Manual

Page of 2574
ISDN-TRK (DS1 ISDN Trunk)
Issue 1 June 2005
1453
 
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 1: Disagreement between this switch and the switch at the other end of the 
trunk connection with regard to the ISDN call state of the DS1 ISDN Trunk. This switch will 
automatically try to recover by clearing the call, (that is, call will be torn down). You can use 
status trunk grp#/mem# to determine the state of the trunk.
When running the short test sequence, pay close attention to the results of the Call State 
Audit test (#257).
c. Error Type 15: Software audit error and does not indicate a hardware malfunction. Run the 
short test sequence, and investigate associated errors.
d. Error Type 19: Possible protocol mismatch or far end may be out of service.
e. Error Type 129: The far-end switch changed its ISDN service state to either out of service 
or maintenance. This may be either a temporary condition due to far-end testing of that 
trunk or a hardware problem with the trunk. Outgoing calls will not be allowed over the trunk. 
To investigate the status of the trunk, enter status trunk grp#/mem#.
513 (
Any
None
WRN
OFF
test port location
769 (
Any
None
test port location
1025 (
0
None
1281
Any
Conference Circuit 
Test (#7)
MAJ
MIN
WRN
1
ON
test port location l r 4
1537
Any
NPE Crosstalk Test 
(#6)
MAJ
MIN
WRN
ON
test port location l r 3
1793 (
Any
None
test port location
3073 (
)
Any
Service State Audit 
(#256)
test port location
3585 (
Any
None
3841 (
Any
None
WRN
OFF
1. Major or minor alarms may be downgraded to Warning alarms based on the value used in the set 
options command.
Table 521: DS1 ISDN Trunk Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 2 of 2