Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1556 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
For the TN2302 and TN2602
When using the TN2302 or TN2602, this test polls the circuit pack for the state of health of a 
specific DSP. If the DSP is bad, an error will be logged and the board will be polled again. If the 
circuit pack is still failing, the DSP will be taken out of service and a MINOR alarm will be raised.
Table 573: DSP Query Test (#1382) 
Error
Code
Test
Result
Description / Recommendation
1014
ABRT
Board not inserted.
1022
ABRT
Board not valid for test.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1–11
FAIL
Some DSPs on the circuit pack have failed. The FAIL code is the number of 
bad DSPs reported (TN802B only).
FAIL
For the TN2302 and TN2602 only, the DSP failed. If it continues to fail, it 
will be taken out of service.
PASS
All 11 DSPs are functioning and in-service.
0
NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board 
(Error Type 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check 
for hyperactivity. If hyperactive, use reset board location.
3. Run the test again. If it fails, the circuit pack may be bad. Replace the 
circuit pack and retest.