Avaya 03-300430 User Manual

Page of 2574
MET-LINE (MET Line)
Issue 1 June 2005
1567
 
Port Diagnostic Test (#35)
This test checks a port's battery feed circuitry. The battery feed circuitry is tested for proper 
battery voltage by testing the switchhook state. In response to the test message, the on-board 
firmware terminates the line and checks for switch-hook presence. The termination is then 
removed, and a check is made for no switch-hook presence. The MET set must be on-hook for 
the test to execute.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list 
config and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout board 
location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
check to ensure that there is a valid board inserted.
Table 578: Test #6 NPE Crosstalk Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 4 of 4
Table 579: Test #35 Port Diagnostic Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 3