Communication Manager Maintenance-Object Repair Procedures
1570 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 580: Test #56 MFAT Electronic Power Feed Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
The test was aborted due to an internal system error on a software 
request to the board.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
FAIL
The test failed with an internal error while it was attempting to turn on the 
EPF.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Electronic Power Feed test passed. The message to turn on the power to 
the station was successfully sent to the port.
1. Although this test will never actually return a FAIL result except for the 
internal system error described above, it will log an error if the 
overcurrent case is detected by the hardware. Check the Error Log for 
any entries with Error Type 257 when the test has completed.
2. If Error Type 257 does not appear in the Error Log within 10 seconds 
after completion of this test, it is safe to assume that the test sensed 
no problems with the power to the station. You can verify that the 
station is powered up correctly by executing a self-test on the station, 
and checking that every feature button is operating.
3. The appearance of Error Type 257 in the Error Log indicates a station 
power problem. Check for a wiring short, a damaged jack, a defective 
voice terminal, or an incorrect type of terminal.