ABRT
The Maintenance/Test and the Pooled Modem boards’ digital ports failed 
to handshake.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test still aborts, replace the Pooled Modem circuit pack.
 2312
ABRT
The Loop-around test did not complete, failed to receive loop-back data.
1. Retry the test, if still aborts, replace the Pooled Modem board.
 2313
ABRT
The Maintenance/Test board’s digital port allocated for this test did not 
respond to down-linked message.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, replace the MTB.
 2314
ABRT
The Modem Pool digital port did not respond to downlinked message. 
This error is internal to the Modem Pool circuit pack and does not involve 
external equipment or interfaces.
1. Busyout the TN758 Pooled Modem conversion resources on the 
circuit pack.
2. If the test continues to abort, replace the Pooled Modem circuit pack 
and retest.
 2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2323
ABRT
The Maintenance Test circuit pack digital port allocated for this test did not 
disconnect properly. This error is more closely related to the Maintenance 
Test circuit pack digital port used for this test than the TN758 Pooled 
Modem circuit pack itself. Therefore, any hardware testing or replacement 
activities will focus on the Maintenance Test circuit pack.
1. Wait 1 minute and attempt the test again up to 5 times.
2324
ABRT
The digital portion of the tested Modem Pool port did not disconnect 
properly.
1. Wait 1 minute and attempt the test again.
2. If the test continues to abort, replace the Pooled Modem circuit pack 
and retest.
Table 624: Test #98 Modem Pool Conversion Resource Loop-Around Test  (continued)