Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1694 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
5011
ABRT
The Network Control Channel allocated for this test did not disconnect 
properly.
1. Follow the repair procedures for Error Code 5001.
5012
ABRT
The digital portion of the tested Modem Pool Port did not disconnect 
properly.
1. Follow the repair procedures for Error Code 5000.
5013
FAIL
The Modem Pool Port did not respond with an on-hook message when 
the connection to the Data Channel was broken, indicating a likely 
problem with the TN758 Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5014
ABRT
The Network Control Channel allocated for this test did not respond 
correctly to the setup message sent to it after the connection was 
established.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack using the 
test data-module command (refer to the DATA-CHL maintenance 
strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the problem.
5015
ABRT
Data Channels 1 and/or 3 have not been administered.
1. Administer the Data Channels and retest.
PASS
The port can correctly transmit/receive data.
Table 624: Test #98 Modem Pool Conversion Resource Loop-Around Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 6 of 6