Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1696 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
M/T-ANL (Maintenance/Test Analog Port)
S8700 | 8710
 / 
S8500
The Maintenance/Test analog port is port number 1 on the TN771D Maintenance/ Test circuit 
pack. This port is used by the Automatic Transmission Measurement System (ATMS) as an 
Originating Test Line (OTL) or Terminating Test Line (TTL) for test calls over analog trunks. For 
more details, see 
 in Maintenance Procedures 
(03-300192)
 shows a typical ATMS configuration.
M/T-ANL maintenance ensures that the analog trunk’s testing function is operating correctly. 
Although an M/T-ANL alarm can reduce service, it will not block service. To accurately measure 
the performance and health of analog trunks, replace an alarmed TN771D when a new circuit 
pack is available.
Figure 96: ATMS Tie Trunk Test Call
MO Name in 
Alarm Log
Alarm
Level
Initial SAT Command to Run
Full Name of MO
M/T-ANL
MIN
test port location l
Maintenance/Test analog port
M/T-ANL
WRN
release port location
Maintenance/Test analog port
Tie
Trunk
Facilities
Originating
Test Line
(OTL)
TN771
TDM Bus
Terminating
Test Line
(TTL)
TN771
TDM Bus
PBX originating
the test call
PBX terminating
the test call
Tie Trunk
Circuit Pack
Tie Trunk
Circuit Pack