Avaya 03-300430 User Manual

Page of 2574
M/T-ANL (Maintenance/Test Analog Port)
Issue 1 June 2005
1703
 
counter, so that if the port continues to fail during or after Communication Manager demands 
testing, the Angel will send a message to indicate that fact.
This test is only used to send a message to the Angel on the Maintenance/Test circuit pack. 
Therefore, this test should never abort or fail.
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test analog port maintenance software and call 
processing agree on the on-/off-hook status of the Maintenance/Test analog port.
Table 629: Test #270 Clear Error Counters 
Error
Code
Test
Result
Description / Recommendation
PASS
The message to clear the Maintenance/Test circuit pack’s counter for 
Background Maintenance Failures has been sent.
Table 630: Test #566 Hook State Inquiry 
Error
Code
Test
Result
Description / Recommendation
1
ABRT
Switch hook audit timed out. No response was received from the circuit 
pack for information about the switch hook state.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, replace the circuit pack and repeat the 
test.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
Any
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to fail reset the circuit pack using busyout 
board locationreset board location, and release 
board location
.
3. Retry the command at 1-minute intervals up to 3 times.
PASS
Call processing and Maintenance/Test analog port maintenance software 
agree on the Maintenance/Test analog port hook state.