Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1716 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1004
ABRT
The port was seized by a valid ISDN-PRI test call. Use list 
isdn-testcall
 to determine which call is using the port (from the M/T 
Port column). Wait for the test call to complete as indicated in the Start 
Time
 and Duration fields of the above display, or abort the test call with 
clear isdn-testcall grp#/mem# where grp#/mem# is 
determined from the B-channel field of list isdn-testcall.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the 
problem.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the test at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the test at 1-minute intervals up to 5 times.
7
FAIL
Conference test failed on the primary information channel. In most 
cases, the user may not notice a disruption in service.
1. Run the circuit pack tests to check the Tone Generator circuit pack 
and the Tone Detector circuit pack using test board location.
2. Resolve any problems that are detected on the Tone Generator 
circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are 
functioning properly, and the test still fails, replace the Maintenance/
Test circuit pack.
14
FAIL
The primary information channel is not transmitting properly. User 
impact may range from nothing to not being able to use this port.
1. Run the circuit pack tests to check the Tone Generator circuit pack 
and the Tone Detector circuit pack using test board location.
2. Resolve any problems that are detected on the Tone Generator 
circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are 
functioning properly, and the test still fails, replace the Maintenance/
Test circuit pack.
PASS
The Maintenance/Test digital port digital trunk testing capability is 
operating correctly.
Table 634: Test #13 Digital Port Loop-Around Test  (continued)
Error
Code
Test
Result
Description / Recommendation