Avaya 03-300430 User Manual

Page of 2574
M/T-DIG (Maintenance/Test Digital Port)
Issue 1 June 2005
1715
 
Only one value (Pass, Fail, or Abort) is generated as a result of the two tests. If it fails or aborts, 
the sequence is stopped.
Table 634: Test #13 Digital Port Loop-Around Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1000
ABRT
The port is use on a valid ISDN-PRI test call. Use list 
isdn-testcall
 to determine which call is using the port (from the M/T 
Port column). Wait for the test call to complete as indicated in the Start 
Time
 and Duration fields, or abort the test call with clear 
isdn-testcall grp#/mem#
, where grp#/mem# is determined from 
the B-channel field of list isdn-testcall.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the 
problem.
1001
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots out-of-service 
due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, repeat the test at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of tone detectors present, or some 
tone detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals 
up to 5 times.
4. If the test continues to abort, escalate the problem.
 1 of 2