Avaya 03-300430 User Manual

Page of 2574
PDMODULE (Processor Data Module)
Issue 1 June 2005
1759
 
1000
ABRT
System resources required to run this test are not available. The port 
may be busy with a valid call.
1. Use display port location to determine the extension of the 
data module port. Use status data-module to determine the 
service state of the port. If the port is in use, wait until the port is idle 
before testing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
1001
ABRT
System resources to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of tone detectors present or some tone 
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 
times.
1004
ABRT
The port may be busy with a valid call.
1. Use display port location to determine the extension of the 
data module port. Use status data-module to determine the 
service state of the port. If the port is in use, wait until the port is idle 
before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1020
ABRT
Test disabled by background testing. Use status data-module to 
determine when the data module is available for testing.
G700
:
1412
ABRT
This test does not execute on a G700 media gateway.
Table 651: Test #9 NPE Crosstalk Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3