Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1762 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1001
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, repeat the test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of tone detectors present or some tone 
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the data module 
extension. Use status data module with the extension number to 
determine the service state of the data module. If the data module is 
in use, wait until the port is idle before retesting.
G700
:
1412
ABRT
This test does not execute on a G700 media gateway.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
:2001
ABRT
System resources required to run this test are not available.
1. Retry the test at one-minute intervals a maximum of 5 times.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Table 652: Information and Control Channel Local Loop Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3