Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1796 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2077
ABRT
The Maintenance/Test Circuit Pack Query located more than one 
Maintenance/Test packet bus port in the PN.
The software should not allow this to occur. This is an internal system 
error. Escalate the problem, but also attempt the following work-around 
steps.
1. Remove every Maintenance/Test circuit pack from the PN.
2. Insert one Maintenance/Test circuit pack (there should not be more 
than one in a PN).
3. Re-enter the test command.
2100
ABRT
Maintenance could not allocate every necessary system resource to 
perform this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The Maintenance/Test packet bus port has detected faults on the Packet 
Bus. The Error Codes are interpreted as follows:
Table 665: Test #572 Maintenance/Test Circuit Pack Query Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3