Avaya 03-300430 User Manual

Page of 2574
PKT-BUS (Packet Bus)
Issue 1 June 2005
1797
 
1xxx
The Maintenance/Test packet bus port has reconfigured the packet bus 
around the faulty leads. This action only occurs in a high- or 
critical-reliability system (duplicated PNC).
2xxx
The Maintenance/Test packet bus port is unable to correct every Packet 
Bus fault it has detected.
x0xx
None of the packet bus faults are open faults.
x1xx
At least some of the packet bus faults are open faults. Look for Error Type 
2305 in the Error Log. The Aux Data value indicates the number of open 
leads.
xxyy
The last two digits of the Error Code indicate the total number of faulty 
packet bus leads detected.
Examples: 
Error Code 2003 FAIL: The Maintenance/Test packet bus port has 
detected 3 faulty leads. None of them are opens. At least one was 
unable to be corrected.
Error Code 1103 FAIL: The Maintenance/Test Packet Port has 
detected 3 faulty leads. At least one is an open. The Maintenance/
Test circuit pack was able to correct all of them by reconfigured.
1. See 
 in Maintenance 
Procedures (03-300192).
PASS
No faults have been detected on the packet bus by the Maintenance/Test 
circuit pack. This is an indication that the packet bus is operating correctly.
Table 665: Test #572 Maintenance/Test Circuit Pack Query Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3