Communication Manager Maintenance-Object Repair Procedures
1798 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Packet Circuit Pack Audit Test (#573)
This test determines whether Packet circuit packs have reported Packet Bus-related in-line 
errors within the last minute. If so, the failure code indicates whether one or more than one 
circuit pack has reported such failures.
If the test has failed within the last 5 minutes, there is a 15 second delay before the result is 
returned. This prevents a repeated sequence of this test from always reporting the same result. 
If the test passes and a FAIL has not occurred within the last five minutes, a PASS is returned 
immediately.
Table 666: Test #573 Packet Circuit Pack Audit Test 
Error
Code
Test
Result
Description / Recommendation
2500
ABRT
An internal operation failed; the test could not be repeated.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
One Packet circuit pack has reported packet bus-related in-line errors 
within the last minute.
2
FAIL
More than one Packet circuit pack has reported packet bus-related in-line 
errors within the last minute.
PASS
No Packet circuit packs have reported packet bus-related in-line errors 
within the last minute. This indicates that the packet bus is healthy, or that a 
packet bus fault is transient or is being caused by a faulty Packet circuit 
pack. If this test passes, but there are other signs of a packet bus failure 
(for example, logged errors or alarms, or other test failures), see 
 in Maintenance Procedures (03-300192).