Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1908 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
3. Use display system-parameters maintenance to see the start time of daily 
maintenance.
4. If the error occurs and is resolved during of daily maintenance, it can be ignored.
e. Error Type 1025: the CDR output device is in an off-line state, (for example, due to paper 
jam or paper out for a printer device). The CDR link is torn down. 
1. Check the CDR output device and act promptly to put it back to on-line state. 
2. Enter test cdr-link primary | secondary command to set up the CDR link.
f. Error Type 1281: overflow of CDR records generated in the switch due to the heavy trunk 
traffic and low speed CDR output device. If both primary and secondary links are ON, the 
secondary link is torn down temporarily for two minutes to speed up the output process to 
the primary link. No action is necessary for this error type.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
Link Tear Down test (#213)
X
Destructive
Link Retry test (#215)
X
X
Nondestructive