Avaya 03-300430 User Manual

Page of 2574
PRI-CDR (Call Detail Recording Link)
Issue 1 June 2005
1909
 
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external CDR output device. 
If the link has already been disconnected, the test returns PASS. Every resource allocated for a 
CDR link is released after this test.
Table 698: Test #213 Link Tear Down Test 
Error
Code
Test
Result
Description / Recommendation
40
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
50
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1010
ABRT
The CDR link has been busied out to out-of-service.
1. Enter the release cdr-link primary | secondary 
command to release the CDR link from busyout state.
2. Retry the test cdr-link primary | secondary long 
command to execute the test.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS