PS-RGEN (Power supply ring generator)
Issue 1 June 2005
1915
2028
ABRT
There is a problem communicating with the environmental maintenance
firmware.
firmware.
1. Enter test maintenance nn to verify communication with the port
network.
2100
ABRT
The system could not allocate resources.
1. Repeat the command at one-minute intervals 1 to 3 times.
2. If the test continues to abort escalate the problem.
2319
ABRT
The EPN is out of range.
2500
ABRT
An internal operation failed.
1. Repeat the command at one-minute intervals 1 to 3 times.
2. If the test continues to abort escalate the problem.
1
FAIL
There is no ringing voltage on the backplane when interchanging the ring
generator to this power supply.
generator to this power supply.
1. Run test board.
64
FAIL
Unable to interchange the ringers, because the power supply being tested
has its ringer turned off.
65
FAIL
Unable to interchange the ringers, because the power supply not being
tested has its ringer turned off.
PASS
The ring generation on redundant power supplies is successfully
interchanged.
NO
BOARD
Power supply is administered but not detected.
1. Verify that the power supply is plugged in.
2. If the power supply was already plugged in, replace the power supply.
Table 702: Test #1539 Ring generator interchange (continued)
Error
Code
Code
Test
result
result
Description and recommendation