Avaya 03-300430 User Manual

Page of 2574
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2067
 
115
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 15 over the 
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 
15. Use display errors to find any SNI-BD errors and check 
display alarms to see if the errors have on-board alarms. Then 
follow the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit 
packs with SNI-PEER Error Type 2561. If other SNI circuit packs have 
SNI-PEER Error Type 2561, then replace the SNI in slot 15. 
Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 2561 errors, 
the problem could be at either of the peer SNI boards. It is arbitrary as to 
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 15.
116
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 16 over the 
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 
16. Use display errors to find any SNI-BD errors and check 
display alarms to see if the errors have on-board alarms. Then 
follow the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit 
packs with SNI-PEER Error Type 2817. If other SNI circuit packs have 
SNI-PEER Error Type 2817, then replace the SNI in slot 16. 
Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 2817 errors, 
the problem could be at either of the peer SNI boards. It is arbitrary as to 
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 16.
Table 749: TEST #755 SNI Circuit Path Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 8 of 11