System Technician-Demanded Tests:
Descriptions and Error Codes
S8700 MC
: If Stratum 3 is administered using change synchronization, the Stratum-3 Clock 
Alarm Query test (#649) also executes when test synchronization is run. Test #649 is 
Test Synchronization Test (#417)
This test updates every Synchronization Maintenance component with the correct information 
about its role in providing a system’s synchronization. This test updates every:
IPSI circuit pack’s Tone-Clock circuit
Tone-Clock, Expansion Interface, DS1 Interface, and UDS1 Interface circuit pack in the 
system. The test either passes or aborts.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
Test Synchronization test (#417) X
X
ND
Table 773: Test Synchronization Test (#417) 
Error
Code
Test
Result
Description / Recommendation
Blank
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1000
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
1115
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS
The Synchronization Maintenance component circuit-pack parameters have 
been successfully updated. The system should be synchronized after 
successful execution of this test. If synchronization problems still exist, refer 
to the Error Log to obtain information about the source of the problem.