TBRI-BD (TN2185 ISDN Trunk-Side BRI)
Issue 1 June 2005
2195
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 1: the circuit pack stopped functioning or was physically removed from the 
system.
Note:
Note:
This alarm logs approximately 11 minutes after removing the circuit pack and/or 
the SAKI Sanity test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot as the error 
indicates. See note (h) for additional information.
c. Error Type 257: transient communication problems between the switch and this circuit 
pack. Execute test board location and refer to the repair procedures for the 
1537 (