2196 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
d. Error Type 513: on-board hardware failure. Aux Data values correspond to the following 
detected errors:
Use busyout board location and reset board location to reset the circuit pack. 
When reset, the circuit pack executes a set of tests to detect the presence of any of the 
faults listed above. Detection of one of these errors during initialization causes the circuit 
pack to lock-up and appear insane to the system. See the repair procedure in Note (
e. Error Type 769: the circuit pack detects a program logic error. While no action is required, 
this error can lead to other errors against this circuit pack.
f. Error Type 1025: the circuit pack cannot update and read back NPE/NCE memory. This 
error can be ignored, but may lead to other errors against this circuit pack.
g. Error Type 1291: the TN2185 board notifies maintenance software that it has detected a 
parity error while accessing its dynamic RAM (memory that stores the board’s translation 
information and downloadable application firmware). Maintenance software resets the 
circuit pack.
h. Error Type 1294: unable to write LAN Translation RAM Error (internal memory access 
error). Translation RAM locations for the call connection attempt are not available, and one 
or more RAM locations are bad due to a translation RAM read-back error. Reset the circuit 
pack with busyout board location and reset board location. If the Circuit Pack 
Restart test (#594) passes, then the on-board circuitry is healthy. Retire the alarm with 
test board location long clear. If the Circuit Pack Restart test (#594) fails, replace 
the circuit pack.
i. Error Type 1537: frame overrun at Packet bus interface. This condition is due to an 
on-board fault or by faulty data received on one of the circuit pack’s external ports. If any of 
the ports on this circuit pack is alarmed, refer to the repair procedures for those MOs. If this 
error persists, maintenance software removes the board from service; replace the circuit 
pack.
4352
External RAM error
4353
Internal RAM error
4355
ROM Checksum error
4357