Avaya 03-300430 User Manual

Page of 2574
TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 June 2005
2219
 
1
FAIL
Received a status of Level 1 Pending Activation. U interface down 
indicating a problem with a connection between the switch and the 
NT1, a 2- to 4-wire converter that is used to connect 4-wire terminals 
to a 2-wire TN2198 or TN2185 circuit pack.
2. Verify that the connections between the switch and the NT1 are 
good. Verify that the NT1 has power.
3. Execute test port location and review the results of the 
Level 1 Status Query test to verify the repair. If this test still fails, 
proceed to Step 3.
4. Follow the manufacturers repair procedures for the NT1. Then 
execute test port location and review the results of the 
Level 1 Status Query test to verify repair.
2
FAIL
Received a status of Level 1 Pending Activation. U interface up, S/T 
interface down, which indicates a problem with the NT1 or the wiring 
between the NT1 and the BRI endpoint (S/T interface).
5. Execute test port location and review the results of the 
Level 1 Status Query test to verify the repair. If this test still fails, 
proceed to Step 2.
6. Follow the manufacturer-recommended repair procedures for 
the NT1. Then execute test port location and review the 
results of the Level 1 Status Query test to verify repair.
Table 793: Test #1242 Level 1 Status Query  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3