Avaya 03-300430 User Manual

Page of 2574
TIE-DS1 (DS1 Tie Trunk)
Issue 1 June 2005
2275
 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Note:
Note:
For TN767B vintage 8 or 9 circuit packs, a failure of Test #136 causes a 
subsequent failure of Test #7. Test #136 is part of the short sequence and 
generates off-board alarms Test #7 is part of the long sequence and generates 
on-board alarms. Before entering busyoutreleasereset or test board 
location
 long commands, check the vintage number of the circuit pack with 
list configuration board location. If it is TN767B vintage 8 or 9, do 
not use the above commands until first making sure that Test #136 passes using 
test board location short. Otherwise, extraneous on-board alarms may 
be generated.
NPE Crosstalk Test (#6)
Note:
Note:
S8500
 / 
G700
: This test aborts with Error Code 1412 on the G700.
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot and 
never crosses over to time slots reserved for other connections. If the NPE is not working 
correctly, 1-way and noisy connections may be observed. This test is usually only part of a 
port’s long test sequence and takes on the order of 20 to 30 seconds to complete.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6)
S8500
 / 
G700
: Aborts with Error Code 1412 on a G700.
X
ND
Conference Circuit test (#7)
S8500
 / 
G700
: Aborts with Error Code 1412 on a G700.
X
ND
DS1 Tie Trunk Seizure test (#136)
X
X
ND
Port Audit and Update test (#36)
X
X
ND