Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2284 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 Interface circuit 
pack or media module to ensure that the trunk’s translation is correct. Translation updates 
include the following data: trunk type (in/out), dial type, timing parameters, and signaling bits 
enabled. The port audit operation verifies the consistency of the current state of the trunk kept 
by the DS1 Interface circuit pack or media module and the switch software.
Table 817: Test #36 Port Audit and Update Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test were not available. The port 
may be busy with a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the 
service state of the port. If the service state indicates that the port is in 
use, then the port is unavailable for certain tests. Wait until the port is 
idle before retesting.
2. If the port status is active but the port is idle (no calls), check the error 
log for Error Type 1025 (see the error log table for a description of this 
error and required actions). The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
1006
ABRT
The test was aborted because the trunk is out of service.
1. Use status trunk to verify that the trunk is out of service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, enter release trunk to 
restore the trunk’s service, and then retry the test.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2