TIE-DS1 (DS1 Tie Trunk)
Issue 1 June 2005
2285
 
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Trunk translation has been updated successfully. The current trunk states 
kept in the DS1 Interface circuit pack or media module and switch 
software are consistent. If the trunk is busied out, the test does not run but 
returns a PASS. To verify that the trunk is in-service:
1. Enter status trunk to verify that the trunk is in-service. If the trunk 
is in-service, no further action is necessary. If the trunk is 
out-of-service, continue to step 2.
2. Enter release trunk to put the trunk back into in-service.
3. Retry the test command.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board’s translations are correct. Use list 
configuration, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long 
This should re-establish the linkage between the internal ID and the port. If 
not, check that there is a valid board inserted.
Table 817: Test #36 Port Audit and Update Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2