0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board’s translations are correct. Use list 
config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. If 
this is not the case, check to see that there is a valid board inserted.