Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2288 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1020
ABRT
The test did not run due to an already existing error on the specific port or 
due to a more general circuit pack or media module error.
1. Examine the error log for existing errors against this port or the circuit 
pack or media module and attempt to diagnose the already existing 
error.
2. Retry the test.
1040
ABRT
The test is invalid for this trunk port because it is administered as an 
access endpoint.
1. Use display port location to verify that this port is administered 
as an access endpoint. In this case the test should abort.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABRT/
FAIL
At least one of the following errors is found on the DS1 circuit pack or 
media module: 1281 – Loss of Signal, 1793 – Blue alarm, 2049 – Red 
alarm, 2305 – Yellow alarm, or 1537 – Hyperactivity.
1. Look for the previous Error Types in the Hardware Error Log, and 
follow the procedures given in the appropriate DS1-BD, UDS1-BD, or 
MG-DS1 maintenance documentation for the listed Error Types.
Earlier G1 software versions reported Error Code 2053 as a FAIL.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 818: Test #136 DS1 Tie Trunk Seizure Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 5