TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005
2325
 
FAIL
Measured transmission performance was in the unacceptable range as 
administered on the trunk group screen. Retrieve a measurement report 
using list testcalls. Make sure that ATMS thresholds are set properly 
on page 4 of the trunk group screen. Besides the facility, test failures can be 
caused by faulty test lines or switch paths. If the measurements point to a 
facility problem, report the results to the trunk vendor.
FAIL
Measured transmission performance was in the unacceptable range as 
administered on the trunk group form. Retrieve a measurement report using 
the list testcalls command. Make sure that ATMS thresholds are set 
properly on page 4 of the Trunk Group form. Besides the facility, test failures 
can be caused by faulty test lines or switch paths. If the measurements point 
to a facility problem, report the results to the trunk vendor.
8000
FAIL
Measured transmission performance was in the marginal range as 
administered on the trunk group screen. This generally means that the trunk 
is usable but has an undesirable amount of noise or loss. If the user does 
not report unacceptable effects, it may not be necessary to take any action. 
Retrieve a measurement report using list testcalls. Make sure that 
ATMS thresholds are set properly on page 4 of the Trunk Group screen.
Table 834: Test #844-848 Transmission Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 5 of 5