Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2372 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
4. Enter display alarms and determine the location of the circuit pack with the alarmed 
GPTD-PT, DTMR-PT, or GPTD-PT.
Run test board location l r 3 for that circuit pack.
If this does not clear the TTR Level alarm, replace the Tone Detector or Call Classifier circuit 
pack with the alarmed GPTD-PT, DTMR-PT, or CLSFY-PT.
Error Log Entries and Test to Clear Values
!
WARNING:
WARNING:
The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12 
(France).
Notes:
a. Error Type 1: does not indicate a current error condition. It indicates that the number of 
DTMR ports in service was below the administered threshold, but is now equal to or greater 
than the threshold. These errors are typically generated during boot time or other 
transitional states when the ports are being brought into service.
b. Error Type 2: the total number of DTMR ports currently in service is below the administered 
threshold. To clear the alarm, see 
c. Error Type 3: does not indicate a current error condition. It indicates that the number of 
GPTD ports in service was below the administered threshold, but is now equal to or greater 
Table 849: TTR Level Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm 
Level
On/Off
Board
Test to Clear Value
)
1
None
)
2
WRN 
(See message below)
OFF
3
None
)
4
WRN
OFF
)
5
None
)
6
WRN
OFF
)
7
MAJ
OFF
)
8
MIN
OFF
9
MIN
OFF