Communication Manager Maintenance-Object Repair Procedures
2442 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1 to 17  FAIL
The test failed because the UDS1 interface circuit pack detected errors in 
the received framing bits pattern. The Error Code equals the number of 
misframes detected by the UDS1 interface circuit pack since the last 
misframe alarm inquiry test. Major bit and minor bit error rate (Error Types 
2561 and 2817) error logs often accompany misframe alarms. Clearing 
the cause of these error logs may clear the misframes which are 
occurring.
If the UDS1 connects to a T1 network facility or to another switch, do the 
following:
1. Retry the command at 1-minute intervals up to 5 times.
2. If the DS1 interface circuit pack is a TN464C, enter list 
measurement ds1-log location to read the error seconds 
measurement.
3. Verify that both endpoints of the DS1 link are administered using the 
same signaling mode, framing mode, and line coding.
4. Check the active alarm and error logs for recent alarms and errors 
against the synchronization (SYNC). Follow the suggested repair 
procedure for these errors.
5. Contact T1 Network Service or the technician at the remote switch to 
diagnose the remote DS1 endpoint.
6. Check the physical connectivity of the UDS1 interface circuit packs 
and the cable.
7. Replace the local UDS1 interface circuit pack, and repeat the test.
Table 865: Test #145 Misframe Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 5