Avaya 03-300430 User Manual
UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2443
1 to 17 FAIL
(
cont’d
)
If the UDS1 connects to a line-side terminating device such as a PRI
terminal adapter:
terminal adapter:
1. Retry the command at 1-minute intervals up to 5 times.
2. Enter the list measurement ds1-log location command to
read the error seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are
administered using the same signaling mode, framing mode, and
line coding.
line coding.
4. Investigate the maintenance status of the line-side terminating
device. Refer to the Line-Side Terminating Device Operating Manual
for information.
for information.
5. Contact the vendor of the line-side terminating device to diagnose
the equipment.
6. Check the physical connection of the UDS1 interface circuit pack to
the terminating device, and check the premise distribution system
(or the intra-premise wiring) for physical connection failures.
(or the intra-premise wiring) for physical connection failures.
7. Replace the local UDS1 interface circuit pack and repeat the test.
PASS
No Misframe alarm is detected on the UDS1 Interface circuit pack.
Table 865: Test #145 Misframe Alarm Inquiry Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
4 of 5