UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2443
 
1 to 17 FAIL
(
cont’d
)
If the UDS1 connects to a line-side terminating device such as a PRI 
terminal adapter:
1. Retry the command at 1-minute intervals up to 5 times.
2. Enter the list measurement ds1-log location command to 
read the error seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and 
line coding.
4. Investigate the maintenance status of the line-side terminating 
device. Refer to the Line-Side Terminating Device Operating Manual 
for information.
5. Contact the vendor of the line-side terminating device to diagnose 
the equipment.
6. Check the physical connection of the UDS1 interface circuit pack to 
the terminating device, and check the premise distribution system 
(or the intra-premise wiring) for physical connection failures.
7. Replace the local UDS1 interface circuit pack and repeat the test.
 
PASS
No Misframe alarm is detected on the UDS1 Interface circuit pack.
Table 865: Test #145 Misframe Alarm Inquiry Test  (continued)