Avaya 03-300430 User Manual
WAE-PORT (Wideband Access Endpoint Port)
Issue 1 June 2005
2533
b. Error Type 130: the circuit pack or media module has been removed or has been insane for
more than 11 minutes. To clear the error, reinsert or replace the circuit pack or media
module.
module.
c. Error Type 1281: the Conference Circuit test (#7) failed on this port. See Test #7 for repair
procedures.
d. Error Type 1537: the NPE Crosstalk test (#6) failed on this port. See Test #6 for repair
procedures.
e. Error Type 1793: the TN464C UDS1 Interface circuit pack or the MM710 DS1 Interface
Media Module has failed. See
f. Error Type 3840: the Port Audit and Update test (#36) failed due to an internal system
error. Enter status access-endpoint extension and verify the status of the port. If
the wideband access endpoint port is out of service, enter release access-endpoint
extension to put it back into service. Retry the test command.
extension to put it back into service. Retry the test command.
System Technician-Demand Tests: Descriptions and Error Codes
Investigate tests in the order listed below when inspecting errors in the system. By clearing
Error Codes associated with the NPE Crosstalk test (#6), you may also clear errors generated
from other tests in the testing sequence.
Error Codes associated with the NPE Crosstalk test (#6), you may also clear errors generated
from other tests in the testing sequence.
Order of Investigation
Short Test
Sequence
Sequence
Long Test
Sequence
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6)
G700
: On the G700, this test aborts with Error Code 1412.
X
ND
Conference Circuit test (#7)
G700
: On the G700, this test aborts with Error Code 1412.
X
ND
Port Audit and Update test (#36)
X
X
ND