Avaya 03-300430 User Manual
AESV-LNK (AE Services Link)
Issue 1 June 2005
371
AESV-LNK (AE Services Link)
S8700 | 8710
/
S8500
/
S8300
AESVCS Links provide a connection between Communication Manager and an AESVCS
Server in which data is exchanged. Communication Manager dynamically creates and deletes
AESVCS Links as socket connections to AESVCS Server are established and torn down.
AESVCS Links that are connected to the same AESVCS Server are grouped into an AESVCS
Session.
Server in which data is exchanged. Communication Manager dynamically creates and deletes
AESVCS Links as socket connections to AESVCS Server are established and torn down.
AESVCS Links that are connected to the same AESVCS Server are grouped into an AESVCS
Session.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 513 is displayed when an AESVCS Link is hyperactive. The hyperactivity might
be caused by fluctuations in the engineered traffic load being generated by the AESVCS
Server. Both an AESVCS Session level and Link level alarm is generated to indicate that a
link is overloaded.
Server. Both an AESVCS Session level and Link level alarm is generated to indicate that a
link is overloaded.
Once the problem has been resolved, it might take up to 45 minutes for the alarm to clear
due to the “leaky bucket” strategy. If the hyperactivity persists, escalate the problem.
due to the “leaky bucket” strategy. If the hyperactivity persists, escalate the problem.
MO Name in Alarm Log
Alarm
Level
Level
Initial Command to Run
Full Name of MO
AESV-LNK
MAJ
WRN
WRN
test aesvcs-server
Application Enablement
Services (AESVCS)
Link
Table 103: AESV-LNK Error Log Entries
Error Type
Aux
Data
Data
Associated
Test
Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
513 (
)
WRN
Off
none
769 (
)
AESVCS
Link
Heartbeat
Test (#1324)
Log
only
Any
Log
only
)
Log
only