Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
384 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ANL-16-L (16-Port Analog Line)
S8700 | 8710
/
S8500
The circuit packs listed below provide 16 analog line ports for single-line voice terminals. The
table below indicates which circuit packs are equipped with lightning protection (for
off-premises, out-of -building stations), and which ones support the neon message waiting lamp
feature.
table below indicates which circuit packs are equipped with lightning protection (for
off-premises, out-of -building stations), and which ones support the neon message waiting lamp
feature.
S8700 | 8710
/
S8500
These circuit packs provide 16 ports for analog voice terminals. The TN746, TN468, and TN749
support only single-line, on-premises/in-building, analog voice terminals, and not off-premises
stations, since these circuit packs are not equipped with lightning protection. The TN746B,
TN2144, TN2149, and TN468B support both on-premises and off-premises (that is,
out-of-building) analog voice terminals. The TN468, TN468B, TN479, TN2135, TN2144, and
TN2149 do NOT support the neon message waiting feature.
support only single-line, on-premises/in-building, analog voice terminals, and not off-premises
stations, since these circuit packs are not equipped with lightning protection. The TN746B,
TN2144, TN2149, and TN468B support both on-premises and off-premises (that is,
out-of-building) analog voice terminals. The TN468, TN468B, TN479, TN2135, TN2144, and
TN2149 do NOT support the neon message waiting feature.
No maintenance of the terminal connected to the 16-Port Neon Analog Line circuit pack is
performed, except to determine whether or not the terminal is connected. Failures of the neon
message waiting lamp power and the common ringing application circuitry are reported as part
of common port circuit pack errors; see errors 1281 and 1793 in
performed, except to determine whether or not the terminal is connected. Failures of the neon
message waiting lamp power and the common ringing application circuitry are reported as part
of common port circuit pack errors; see errors 1281 and 1793 in
MO Name in Alarm Log Alarm
Level
Initial Command to Run
Full Name of MO
ANL-16-L
MIN
test port location l
16-Port Analog Line
ANL-16-L
WRN
test port location sh
16-Port Analog Line
16-Port Analog Line Circuit Packs
Circuit Pack
Off- Premises
Neon
TN468B
y
TN479
TN746
y
TN746B
y
y
TN2135
y
TN2144
y
TN2149
y
TN2180
y