1000
ABRT
System resources required to run test are not available. The port may be 
busy with a valid call. This result is also reported for the system’s 
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port location to determine the station’s 
extension. Enter status station extension to determine the 
service state of the port. If the port is active, wait until it is idle.
2. Retry the command at 1-minute intervals up to 5 times.
1001
ABRT
System resources required to run test are not available. This could be due 
to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or have time slots out-of-service due to 
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of Tone Detectors present, or some 
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use the display port location command to determine the 
station extension. Use status station to determine the service 
state of the port. If the port is active, wait until the it is idle before 
testing.
2. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
The test was aborted due to a configuration problem. This test may not be 
applicable, or it may be disruptive to terminal equipment other than a voice 
terminal (for example, the modem pool member or Music On Hold).
Table 113: Test #6 NPE Crosstalk Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 4