Avaya 03-300430 User Manual

Page of 2574
AN-LN-PT (Analog Line Port)
Issue 1 June 2005
435
 
Battery Feed Test (or Port Diagnostic Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling, rotary dial pulsing, 
transmission, and balance.  This test checks the signaling and switchhook capabilities of the 
battery feed chip by terminating the port, applying battery power, and detecting the resulting 
current.
Table 128: Test #35 Battery Feed Test 
Error 
Code
Test
Result
Description / Recommendation
ABRT
Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1000
ABRT
System resources are unavailable.  The port may be busy with a valid call.  
This result is also reported for the system’s Music-On-Hold port when it is 
off-hook, which it usually is.
1. Enter display port location to determine the station’s 
extension.
2. Enter status station extension to determine the service state of 
the port.
3. If the port is active, wait until it is idle.  Retry the command at 1-minute 
intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1004
ABRT
A valid call seized the port during the test and aborted the test.
1. Use display port location to determine the station extension.
2. Use status station extension to determine the service state of 
the port.
3. If the port is active, wait until it is idle before testing.  Retry the 
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005
ABRT
This test was aborted due to a configuration problem.  The test is not 
applicable for this type of analog port.  This error can be ignored.
 1 of 3