Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
458 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. The Announcement circuit pack can exhibit a condition that does not allow recording.
If the circuit pack gets locked into this state (this is an extremely rare condition), two of the 
Announcement Ports on the circuit pack will be unusable by software, one of which is the 
record port. Also, save/restore announcements will not work, since the record port 
looks busy to the circuit pack. Note that software does not have any way of knowing this, 
and attempts to use the ports.
If the circuit pack is locked into this state, the following symptoms are observed:
1. When attempting to record an announcement, users hear the proper record tone, but the 
announcement do not record (they do not know it until the announcement is played 
back).
2. Performing a test board long when the circuit pack is in this state yield the following 
abort codes:
Ports 1 AND 9 abort Test #206 with code 1024
Ports 1 AND 9 abort Test #205 with code 2000
Board level Tests #209 and #210 abort with code 1024
3. Save/restore announcements times out with:
Error encountered, can’t complete request
The Announcement circuit pack lock-up can be cleared remotely by performing a soft reset 
to the circuit pack:
busyout board PCSS (this command drops all calls in progress on the Announcement 
circuit pack)
Reset circuit pack using reset board PCSS
Release circuit pack using release board PCSS
PASS
All recorded announcements checksum correctly, indicating that the speech 
main memory is functioning properly. User-reported troubles on this circuit 
pack should be investigated using other circuit pack and port tests. Refer to 
on page 465 Maintenance documentation for 
a description of the port tests.
Table 135: TEST #209 announcement checksum test  (continued)
Error
code
Test
result
Description/ Recommendation
 3 of 3