140AY loop around test (#210)
This test checks the integrity of the record channel on the Announcement circuit pack 
(Announcement Port 1). The main function of the 140AY device is to accept Pulse Code 
Modulation (PCM)/Adaptive Differential Pulse Code Modulation (ADPCM) samples and 
compress/expand the samples using ADPCM. This test connects a Tone Generator to one port 
(Announcement Port 1, the recording port), and a Tone Detector to another port (Announcement 
Port 9). A tone is generated by the Tone Generator on the first port and looped through the 
140AY device to the second port. The Tone Detector then responds with a tone present/absent 
message. The 140AY Loop Around Test is repeated at three different speech compression 
rates.
Since this test involves sending a tone through two different ports, the Playback Speech 
Memory Array (PSMA) Test (#206) is run on the two ports first to make sure that they are 
working properly. See 
on page 465 for a description of this test.
Table 136: TEST #210 140AY loop around test 
Error
code
Test
result
Description/ Recommendation
1-3
ABRT
Response to the test request was not received within the allowable time 
period. The error code indicates at which speech compression rate the test 
aborted (one being the first rate tested, three being the last).
1. Retry the command at 1-minute intervals a maximum of 5 times.
10
ABRT
The PSMA Test (#206) failed on Announcement Port 1.
1. Refer to 
documentation, Test #206.
90
ABRT
The PSMA Test (#206) failed on Announcement Port 9.
1. Refer to 
documentation, Test #206.
1000
ABRT
System resources required to run this test are not available. This test needs 
Announcement Ports 1 and 9 to run. One of the ports may be in use on a 
valid call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort and Ports 1 and 9 are not in use, escalate 
the problem.
 1 of 3