Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
546 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1003
ABRT
The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Verify that at least one Tone Detector resides in this PN. (Even
without a TTR-LEV error, the tested circuit pack’s PN could be missing
a Tone Detector.)
a Tone Detector.)
If missing, the test always aborts for this circuit pack, without harming
the system.
the system.
Note:
Note:
A TN2182 Tone-Clock circuit pack in a PN must be of
vintage B or newer. If an earlier vintage resides in a PN,
this test always aborts with this abort code.
vintage B or newer. If an earlier vintage resides in a PN,
this test always aborts with this abort code.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up
to 3 times.
Table 174: Expansion Interface 2-Way Transmission Test (#241) (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 8