Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
548 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1395
ABRT
This test cannot run on an ATM-EI circuit pack if it is part of the B-side 
PNC and Duplicated PNC is not enabled.
1. If this test needs to run on this ATM-EI circuit pack, enable PNC with 
the change system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the 
set PNC lock command.
3. Repeat this test.
1413
ABRT
This test requires the use of a Tone-Clock circuit in each of the PNs used 
in this test.  This abort code indicates that a Tone-Clock circuit is absent 
from one of the PNs.
1. Verify that an IPSI or Tone-Clock circuit pack resides in the same PN 
as the ATM PNC Expansion Interface circuit pack under test.
2. In ATM PNC configurations, make sure that there is at least one other 
PN besides the PN where the ATM-EI circuit pack under test resides 
that contains a Tone-Clock circuit.
1414
ABRT
The active Tone-Clock circuit in one of the PNs being used for the test has 
a MAJOR or MINOR alarm logged against it.
1. Enter display alarms and resolve any TONE-BD and TONE-PT 
alarms.
1956
ABRT
ACL to the board is not up.  See ACL status with list sys-link and 
follow the repair procedures for SYS-LINK.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
2100
ABRT
System resources required to run this test are not available.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The test tone was not detected correctly in either direction.
1. Test the active Tone-Clocks in the PNs for which the ATM-EI circuit 
pack under test provides a link.  This determines if the dial tone is 
supplied.
Table 174: Expansion Interface 2-Way Transmission Test (#241)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 8