Avaya 03-300430 User Manual

Page of 2574
AUX-TRK (Auxiliary Trunk)
Issue 1 June 2005
661
 
Notes:
a. Error Type 0: Run the short test sequence first.  If every test passes, run the long test 
sequence.  Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. *Error Type 1 with Aux Data 57481 indicates a port fault.  Use an empty port if one is 
available until the circuit pack can be replaced.
c. Error Type 1 or 769 with Aux Data 57482 indicates a fault on signaling lead, which is an 
off-board error.  This error should only occur with loudspeaker paging.  If the trunk is being 
used for another application, check that the administration is correct.  Otherwise, check the 
wiring to the external equipment connected to the Auxiliary Trunk and check the external 
equipment.
d. Error Type 15: software audit error that does not indicate any hardware malfunction.  Run 
short test sequence, and investigate associated errors.
e. Error Type 130: the circuit pack has been removed or has been insane for more than 11 
minutes.  To clear the error, reseat or replace the circuit pack.
18
0
busyout port 
location
WRN
OFF
release port location
130(
None
WRN
ON
test trunk grp#/mem# 
sh
769(
)
57482
None
257
Hybrid/Conference
MIN 
WRN
1
ON
test port location l 
r 3
Circuit test (#33)
513
NPE Crosstalk test (#6)
MIN 
WRN
2
ON
test port location l 
r 3
1025
Diagnostic: Auxiliary Trunk 
(#114)
WRN
ON
test port location sh 
r 3
1. Major or Minor alarms may be downgraded to Warning alarms based on the values used in set options.
Table 223: Auxiliary Trunk Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 2 of 2